Suite 3, 1st Floor, A&B Plaza, 88, Ekoro Road, Abule Egba, Lagos State, Nigeria

Direct Acting Pressure Regulator

1 Dival 160 AP
2 Dival 600
3 Dival 700
1 Dival 160 AP

Single-stage pressure-reducing Valves T y p e DIVAL 160AP.
For industrial and chemical engineering applications.
Suitable for natural gas and all non-corrosive gaseous media.

Features

Technical data
  • Accuracy class
  • Available size DN
  • Closing pressure class SG
  • Design pressure
  • Design temperature
  • Flanging
  • Outlet pressure range of Wd
  • Range of inlet pressure bpu
Value
  • up to 5
  • 1"
  • up to 10
  • 85 bar
  • -10 °C + 60 °C
  • class 300-600 RF accordnig to ANSI B16.5.
  • 0,85 to 4,5
  • 1,4 to 85 bar
2 Dival 600

Dival 600 series pressure gas regulators are direct-acting devices for low and medium pressure applications controlled by a diaphragm and counter spring.

The modular design of the Dival 600 series pressure regulators allows the installation of an incorporated slam shut or device for use as an 'in line monitor' on the same body without changing the face-to-face dimension.

Furthermore the truly 'top entry design' allows easy regular maintenance without removing the unit from the line. The features of Dival 600 series regulators make them a product suitable for any application.

Features

Technical data
  • Accuracy class
  • Design pressure
  • Design temperature
  • Flanging
  • Outlet pressure range of Wd
  • Range of inlet pressure bpu
  • Threaded connections
Value
  • up to 5
  • up to 20 bar (290 Psig)
  • -20°C to +60°C (-4°F to +140°F)
  • class PN 16/25 according to ISO 7005-1, ISO 7005-2; class ANSI 150RF according to ANSI B16.5, ASME B16.42 and class ANSI 125 FF according to ASME B16.1
  • DN 25 BP/MP 12 to 340 mbar TR 300 a 4200 mbar DN 40-50 BP 12 to 85 mbar MP 80 a 340 mbar TR 300 to 4200 mbar"
  • 0,1 to 20 bar
  • DN 2" Rp ISO 7-1 or DN 2"NPTF ASME B1.20.1 (only ductile iron)
3 Dival 700

DIVAL 700 series gas pressure regulators are direct-acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These regulators are suitable for use with pre-filtered, non-corrosive gases.

 

Features

Technical data
  • Accuracy class
  • Available size DN
  • Closing pressure class SG
  • Design pressure
  • Design temperature
  • Flanging
  • Outlet pressure range of Wd
  • Range of inlet pressure bpu
Value
  • up to 5
  • 1" (25) - 1"1/2 (40) - 2" (50)
  • up to 5
  • up to 20 bar (290 Psi)
  • -20 °C to +60 °C (-4 to + 140 °F)
  • class PN 16/25 according to ISO 7005-1, ISO 7005-2; class ANSI 150RF according to ANSI B16.5, ASME B16.42 and class ANSI 125 FF according to ASME B16.1
  • 5 to 1454 mbar (2"w.c. to 21psig)
%d bloggers like this: